Tripp Lite PDUMH15HVATNET

$703.46

Tripp Lite PDU Switched ATS 2/2.4KW 200/240V 10 C13 2 C14 3.6M Cords 1URM – IEC 60320 C14 – 10 x IEC 60320 C13 – 200 V AC
208 V AC
220 V AC
230 V AC
240 V AC – 2.40 kVA – Network (RJ-45) – 1U/2U – Horizontal Rackmount 10 C13 2 C14 3.6M CORDS 200/240V

SKU: PDUMH15HVATNET UPC: Brand: Tripp Condition: New Category: Tag:

Description

Tripp Lite PDU Switched ATS 2/2.4KW 200/240V 10 C13 2 C14 3.6M Cords 1URM – IEC 60320 C14 – 10 x IEC 60320 C13 – 200 V AC
208 V AC
220 V AC
230 V AC
240 V AC – 2.40 kVA – Network (RJ-45) – 1U/2U – Horizontal Rackmount 10 C13 2 C14 3.6M CORDS 200/240V

2-2.4kW Single-Phase ATS PDU with Primary and Secondary Inputs for Power Redundancy

Recommended for data centers
server rooms and network closets
this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-foot (3.7-meter) input cords with C14 plugs connect to separate primary and secondary mains circuits
backup generators
UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.

Switches from Primary to Secondary Power Source in Milliseconds

Dynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds
should the primary source fail or become unstable
to ensure your connected equipment operates without interruption. An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding

This switched power distribution unit distributes
monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control
load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring
including the ability to turn on
turn off
reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime
thus lowering the PDU’s total cost of ownership.

Check Essential Functions at a Glance

A front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220
230 or 240V) or low (200 or 208V) voltage.

Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7

The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser
SNMP
telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4
IPv6
HTTP
HTTPS
SMTP
SNMPv1
SNMPv2
SNMPv3
telnet
SSH
FTP
DHCP and NTP.

Reduce Service Calls with Auto Probe Autonomous Device Management

The Auto Probe feature (Firmware 15.5.2 and greater) checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot
set SNMP traps
SNMP OID sets
and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA).

Easy to Install Horizontally in an EIA-Standard 19 in. Rack

This ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.

TAA-Compliant for GSA Schedule Purchases

The PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA)
which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts. Product Type:PDU
Input Voltage:230 V AC
Output Voltage:200 V AC|208 V AC|220 V AC|230 V AC|240 V AC
Input Current:10 A
Protection Type:Overload Protection
Rack Height:1U/2U
Plug/Connector Type:IEC 60320 C14
Input Voltage Range:200 V AC – 240 V AC
Receptacle Type:IEC 60320 C13
TAA Compliant:Yes
Mounting Orientation:Horizontal
Power Rating (Watt):2400 W
Manufacturer Part Number:PDUMH15HVATNET
Manufacturer Website Address:http://www.tripplite.com
Packaged Quantity:1
Manufacturer:Tripp Lite by Eaton
Product Model:PDUMH15HVATNET
Product Name:PDUMH15HVATNET 10-Outlet PDU
Network (RJ-45):Yes
Management:

  • HTTP
  • HTTPSPowerAlert
  • SMTP
  • SNMPv1
  • SNMPv2
  • SNMPv3
  • Telnet
  • SSH
  • FTP
  • DHCP
  • BOOTP and NTP protocols

Package Contents:

  • PDUMH15HVATNET 10-Outlet PDU
  • 10 x C14 plug lock inserts
  • 2 x C13 to C14 power cords
    3.6 m (11.8 ft.)
  • SNMPWEBCARD configuration cable
  • 2 x Mounting brackets
    horizontal
  • 2 x Mounting brackets
    vertical
  • 6 x Screws
  • Owner’s manual
  • Country of Origin:Taiwan
    Environmentally Friendly:Yes
    Environmental Certification:RoHS
    Weight (Approximate):10.41 lb
    Mount Type:Rack-mountable
    Height:1.7″
    Width:17.3″
    Depth:14.4″
    Receptacle Detail:10 x IEC 60320 C13
    Plug/Connector Detail:2 x IEC 60320 C14