Tripp Lite S3M15K2B

$6,276.04

Tripp Lite UPS 3-Phase Smart Online 15kVA/kW 208/220/120/127V 2 Batteries – Tower – 8 Hour Recharge – 6 Minute Stand-by – 120 V AC
230 V AC Input – 120 V AC
208 V AC Output /KW 208/220/120/127V 2 BATTERIES

Description

Tripp Lite UPS 3-Phase Smart Online 15kVA/kW 208/220/120/127V 2 Batteries – Tower – 8 Hour Recharge – 6 Minute Stand-by – 120 V AC
230 V AC Input – 120 V AC
208 V AC Output /KW 208/220/120/127V 2 BATTERIES

Battery Backup and VFI Operation Protect Critical Loads

The SmartOnline® S3M15K2B IGBT UPS supports the continuous availability of your most important operational and IT equipment loads through all power conditions
providing a compact backup power platform that’s easy to manage and inexpensive to operate. Sophisticated voltage- and frequency-independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 15kVA/kW of clean
continuous power
this 3-phase UPS system is ideally suited for critical applications in banking
education
healthcare
government and manufacturing sectors.

Best-in-Class Footprint for Easy Integration into Your Network Application

The UPS market’s smallest footprint for 3-phase 208V systems lets you install the S3M15K2B in spaces that would otherwise have required expensive retrofitting. By achieving its compact size without compromising runtime
reliability or functionality
the S3M15K2B is recommended for data centers
colocation facilities and edge computing environments that require high efficiency
high performance and clean
reliable power protection
while preserving as much space as possible for revenue-generating server racks.

Efficient Operation and Design Reduces Cost of Ownership

ENERGY STAR 2.0-certified technology provides high operational efficiency to save on utility and cooling costs
as well as protect the environment. This UPS achieves up to 94% efficiency in double-conversion mode and up to 98% in ECO mode
reducing your power and cooling costs. Unity output power factor (1.0) lets you support more equipment. A low THDi (<2%) improves generator compatibility. A low THDv (≤1%) and active power factor correction with DSP control improve output performance. The hardware and firmware platform design reduces the number of unique boards
improving mean time to repair (MTTR) and resulting in reduced downtime. Automatic and maintenance bypass transfer UPS load to utility power during faults
overloads and maintenance
which also avoids costly system downtime.

Supplies Reliable Battery Backup with Expandable Runtime Options

Two internal battery modules provide 13 minutes of support at half load and six minutes at full load with zero transfer time. Adding external battery cabinets
such as BP24V09K and BP240V09 (sold separately)
provides extended runtime and supports critical loads uninterrupted during successive utility network outages. A one-touch cold-start button powers up the UPS with battery power only.

Intuitive LCD Interface Delivers Important Performance Information at a Glance

The large five-inch touchscreen LCD panel displays critical operating conditions and diagnostic data
including battery and load status. Four LEDs provide information about AC
bypass
battery and fault status.

Remote Network Monitoring and Control Available 24 Hours a Day

The optional Java-free WEBCARDLXMINI network management card (sold separately) enables remote management through embedded HTML5 web
SSH/telnet and SNMP interfaces
as well as integration with a wide range of network management systems and DCIM platforms. WEBCARDLXMINI also supports EnviroSense2 (sold separately)
which monitors temperature
humidity and other environmental factors. Three MODBUS ports (RS-485
USB
RS-232) may also be used to monitor and manage the UPS. A Remote Emergency Power Off (REPO) port allows shutdown from a safe distance during emergencies.

Application/Usage:Industrial|Data Center|Critical System|Telecommunication|Server Room|Network|Manufacturing Facility|IT Equipment|Edge Computing|Healthcare|Government|Finance|Education|Banking
Product Type:Double Conversion Online UPS
Input Voltage:230 V AC|120 V AC
Form Factor:Tower
Network Management:Telnet|SSH|SNMP Manageable
Waveform Type:Pure Sine Wave
Plug/Connector Type:Hardwired
Phase:Three Phase
Receptacle Type:Hard Wire (3-PH)
Product Family:SmartOnline
Backup/Run Time (Half Load):13 Minute
Backup/Run Time (Full Load):6 Minute
Load Capacity (VA):15 kVA
Energy Star:Yes
Number of Batteries:2
DC System Voltage:120 V DC
Typical Battery Recharge Time:8 Hour
Status Indicators:

Front Panel LCD Display:

  • Large touchscreen color LCD display (5in/ 12.7cm) enables comprehensive local monitoring
  • Diagnostics and control
  • Intuitive and user-friendly interface

Sub-screens Status:

  • Home
  • Status
  • Alarm
  • Setting
  • Maint
  • Common
  • About

LED Indicators:

  • Four LEDs indicate AC mode (Green)
  • Bypass (Yellow)
  • Battery (Yellow)
  • Fault (Red) Modes

Thermal Dissipation:720.08 W
Maximum Operating Temperature:104°F (40°C)
Maximum Operating Elevation:3280 ft
Manufacturer Part Number:S3M15K2B
Manufacturer Website Address:http://www.tripplite.com
Manufacturer:Tripp Lite by Eaton
Product Model:S3M15K2B
Product Name:SmartOnline S3M15K2B 15kVA Tower UPS
Product Line:SmartOnline
Serial Port:Yes
EPO Port:Yes
USB (HID Compliant) Port:Yes
Alarm:Bypass Mode|Low Battery|Overload|Shutdown
Package Contents:

  • SmartOnline S3M15K2B 15kVA Tower UPS
  • RS-232 Cable (Male/Female)
    5 ft. (1.5 m)
  • Parallel Cable (Male/Female)
    5 ft. (1.5 m)
  • USB Cable
    5 ft. (1.5 m)
  • Battery Cable Anderson Connectors Set to Terminate a Battery Cable (2 Black
    2 White
    2 Red and several metal terminals)
  • Cable Glands (x6) for Cable Landing Box (waterproof fasteners)
  • Dry Contact Connector (Green)
  • Owner’s Manual
  • Country of Origin:China
    Environmentally Friendly:Yes
    Environmental Certification:RoHS
    Weight (Approximate):414 lb
    Height:34.2″
    Width:9.8″
    Depth:35.4″
    Output Voltage:208 V AC|120 V AC
    Output Frequency:60 Hz
    Overload Protection:Yes
    EMI/RFI Noise Filter:Yes
    Energy Saving:High efficiency economy mode operation; Schedulable daily hours of economy mode operation
    Transfer Time:0 ns